014727 FebPit 4 Haul Road

Light vehicle entered active exclusion zone while CAT 793 was dumping. No contact, no injuries. LV driver did not see signage due to dusty conditions. Spotter was not in designated position.

Near MissHighOpen
014626 FebProcessing Plant — Level 3

Worker fell approximately 2 metres from scaffolding. Harness was worn but not clipped to anchor point. Landed on platform below, complained of back pain. Scaffolding had green tag from previous day inspection.

Medical Treatment InjuryCriticalUnder Investigation
014525 FebProcessing Plant — Level 1

Two operators reported skin irritation after contact with reagent solution. Standard PPE was worn but not chemical-rated gloves. SDS recommends nitrile gloves for this product.

First Aid InjuryMediumOpen
014424 FebWorkshop Bay 2

Wrench dropped from Level 2 maintenance platform. Landed in walkway below. No personnel in drop zone at the time. Tool tether was not being used.

Near MissMediumClosed
014323 FebCrusher Area

Isolation point for Conveyor C4 found with lock removed during night shift maintenance. Conveyor was energised while maintenance crew believed it was isolated. No injuries — discovered during routine verification.

Hazard ReportHighOpen
014223 FebStockpile Area

Grader operator reversed without completing 360-degree check. Narrowly avoided contact with parked light vehicle behind. Reversing alarm was functional.

Near MissMediumClosed
014122 FebTailings Storage Facility

Minor seepage detected at tailings embankment monitoring point TSF-7. Volume estimated at 2L/hr. Within operational tolerances but trending upward from previous readings.

Environmental IncidentMediumOpen
014021 FebPit 4 Haul Road

Water cart reversed without checking blind spot. Rear proximity alarm was not functioning. Spotter attempted to radio but driver had radio on wrong channel.

Near MissHighClosed
013919 FebPower Station

Switchboard panel cover found unsecured on Unit 3. Arc flash hazard present. Previous maintenance work order had not been closed out properly.

Hazard ReportHighClosed
013818 FebROM Pad

Unsecured load on flat-bed truck shifted during transport on haul road. Material fell onto road surface. Haul truck behind swerved to avoid debris. No contact.

Near MissHighClosed
013718 FebWorkshop Bay 1

Fitter strained lower back while lifting pump component. Weight was within manual handling limit but awkward lifting posture used. First aid administered on site.

First Aid InjuryLowClosed
013617 FebConveyor Belt C4

Conveyor belt tracking issue resulted in belt edge damage over approximately 15 metres. Belt alignment sensor had been flagged as unreliable during previous shift but not repaired.

Property DamageMediumUnder Investigation
013517 FebProcessing Plant — Level 2

Night shift operator reported feeling extremely fatigued and dizzy. Had worked 6 consecutive night shifts. Supervisor observed slow reaction times during routine checks.

Hazard ReportMediumClosed
013417 FebFuel Farm

Minor diesel spill (~50L) during fuel transfer. Secondary containment captured majority. Small amount reached unsealed ground adjacent to bund wall.

Environmental IncidentMediumUnder Investigation
013316 FebPit 2 Ramp

Haul truck and water cart approached single-lane section simultaneously from opposite directions. Both stopped safely. Give-way signage was obscured by dust.

Near MissMediumClosed
013215 FebCamp / Accommodation Village

Unidentified vehicle entered camp area through unmanned gate during shift changeover. Vehicle belonged to a contractor who had not completed site induction. No safety risk identified.

Security IncidentLowClosed
013114 FebProcessing Plant — Level 3

Worker's foot slipped on wet grating at Level 3. Fell through gap in handrail where section had been removed for maintenance. Fell 1.5 metres. Broken wrist confirmed.

Medical Treatment InjuryCriticalUnder Investigation
013013 FebLaydown Area

Crane load (steel beam ~2T) swung unexpectedly during lift due to wind gust. Load came within 2 metres of ground crew. Lift plan had not accounted for afternoon wind changes.

Near MissHighClosed
012911 FebCrusher Area

Crusher jaw liner showed premature wear and partial failure. Fragments entered product stream. No personnel exposure. Unplanned shutdown required for replacement.

Property DamageMediumClosed
012811 FebMain Gate / Weighbridge

Road train driver failed to stop at weighbridge. Drove through boom gate at low speed. Boom gate damaged. Driver reported not seeing stop signal due to sun glare.

Near MissLowClosed
012710 FebExplosives Magazine

Security alarm system for explosives magazine found non-operational during routine check. Last verified operational 72 hours prior. Backup system also offline due to power supply failure.

Security IncidentHighUnder Investigation
012609 FebProcessing Plant — Level 1

Process operator experienced heat exhaustion symptoms during plant walkdown. Core temperature measured at 38.8°C. Ambient temperature was 44°C. Operator had consumed less than 1L water in 4 hours.

First Aid InjuryMediumClosed
012508 FebPit 2 Ramp

Section of pit wall showed signs of instability. Cracks observed along bench face approximately 20 metres above haul road. Geotechnical team confirmed risk of rockfall. Area was active with haulage at the time of discovery.

Serious Potential Incident (SPI)CriticalOpen
012406 FebPit 4 Haul Road

Excavator operator commenced swing while haul truck was still positioning for loading. Bucket passed over truck cab. Operator stated radio communication was unclear.

Near MissMediumClosed
012306 FebWater Treatment Plant

Chlorine dosing pump malfunction led to over-dosing of treated water. Elevated chlorine levels detected at discharge point. Level exceeded licence limit for 2 hours before correction.

Environmental IncidentMediumOpen
012205 FebWorkshop Bay 1

Hydraulic hose on forklift burst during operation. High-pressure fluid sprayed across work area. No personnel struck. Hose was past replacement date per maintenance schedule.

Near MissHighClosed
012104 FebProcessing Plant — Level 2

Entry permit for Ball Mill inspection had expired but crew was still working inside. Gas monitoring equipment battery was flat. Confined space attendant had left post temporarily.

Hazard ReportHighUnder Investigation
012003 FebAdmin Building

Office worker experienced minor paper cut while handling printed reports. First aid kit used to apply bandage. No further treatment required.

First Aid InjuryNegligibleClosed
011901 FebPit 4 Haul Road

Haul truck operator reported near-collision with kangaroo on haul road. Emergency braking applied. Load shifted slightly. Night visibility adequate but wildlife management controls not in place for this section.

Near MissHighClosed
011801 FebLaydown Area

Container being unloaded from flat-bed was set down off-centre on timber dunnage. Container toppled onto side. No personnel in vicinity. Lifting plan not followed.

Property DamageLowClosed
011730 JanROM Pad

Dozer operator encroached on excavator swing radius during ROM pad cleanup. Excavator operator sounded horn. Dozer operator acknowledged and retreated. Communication breakdown identified.

Near MissMediumClosed
011628 JanProcessing Plant — Level 1

Hot bearing detected on conveyor drive pulley via thermal monitoring. Temperature 180°C and rising. Conveyor was carrying coal product. Fire risk assessed as high.

Hazard ReportHighClosed
011527 JanProcessing Plant — Level 3

Worker accessed roof area without fall protection. Was observed by supervisor walking on fragile roof sheeting without safety mesh below. Worker stated he was unaware of the requirement.

Near MissMediumClosed
011425 JanPit 4 Haul Road

Light vehicle overtook haul truck on single-lane section of haul road. Oncoming water cart forced LV to brake heavily and pull off road. Speed and overtaking rules clearly breached.

Near MissHighClosed
011323 JanCrusher Area

Chute liner plate detached and fell into crusher cavity during night shift. No personnel in area at the time. Vibration monitoring had shown elevated readings for 3 days prior.

Near MissMediumClosed
011222 JanWorkshop Bay 2

Mechanic sustained minor laceration to forearm when hand slipped off wrench during bolt removal. Cut approximately 3cm, treated on site with wound closure strips.

First Aid InjuryLowClosed
011120 JanStockpile Area

Haul truck reversed beyond designated dump point on stockpile. Rear wheels came within 3 metres of crest edge. Berm was inadequate height (0.5m instead of required 1.5m).

Near MissMediumClosed
011019 JanProcessing Plant — Level 2

Strong chemical odour detected in pump room. Source identified as minor leak from reagent supply line flange. Volume minimal. Area ventilation was operational.

Hazard ReportLowClosed
010916 JanPit 2 Ramp

Small rockfall (~0.5m³) from bench face landed on haul road berm. Haul truck was approximately 50m away at the time. No contact. Recent blasting may have contributed.

Near MissMediumClosed
010815 JanProcessing Plant — Level 1

Gas monitor alarmed for H2S during tank inspection. Reading peaked at 15ppm (action level 10ppm). Crew evacuated immediately. Ventilation fan had been positioned incorrectly.

Near MissHighClosed
010713 JanPit 4 Haul Road

Drill rig being transported on low-loader failed to display wide load signage. Haul truck approaching from opposite direction had to take evasive action on narrow section.

Near MissMediumClosed
010611 JanWorkshop Bay 1

Welder sustained minor burn to wrist when welding spark entered gap in PPE. Burn approximately 1cm diameter. First aid applied with burn gel and dressing.

First Aid InjuryLowClosed
010510 JanProcessing Plant — Level 3

Loose bolts found on grating panel at Level 3. Panel was unsecured and could have dislodged if stepped on. Area beneath is active walkway. Previous maintenance had not re-secured panel.

Hazard ReportMediumClosed
010407 JanTailings Storage Facility

Return water pipeline showed minor weep at joint. Estimated loss less than 5L over observation period. Pipeline is above ground on the tailings facility access road.

Environmental IncidentLowClosed
010306 JanPit 4 Haul Road

CAT 793 haul truck experienced brake fade on descent from Pit 4. Operator used engine retarder and runaway ramp. Truck safely stopped. Brakes had been flagged for inspection during pre-start but truck was dispatched anyway.

Near MissHighUnder Investigation
010204 JanConveyor Belt C4

Small fire on conveyor belt roller bearing. Detected by thermal camera. Auto-deluge system activated and extinguished fire within 30 seconds. Belt sustained minor surface damage.

Property DamageMediumClosed
010101 JanROM Pad

Excavator commenced loading before haul truck was fully positioned and truck operator had given ready signal. One bucket load dumped onto truck body off-centre, causing load imbalance.

Near MissMediumClosed
010030 DecProcessing Plant — Level 2

Operator experienced eye irritation from airborne dust during grinding circuit inspection. Safety glasses were worn but not sealed type. Flushed with eyewash station.

First Aid InjuryLowClosed
009928 DecCamp / Accommodation Village

Large brown snake observed on walkway between accommodation blocks. Area cordoned off. Snake handler contacted. Snake safely relocated to bushland perimeter.

Hazard ReportLowClosed
009826 DecWorkshop Bay 2

Tyre inflation cage door latch found to be defective during pre-use check. If tyre had been inflated, door could have opened under pressure. Cage taken out of service.

Near MissMediumClosed
009723 DecPit 2 Ramp

Haul truck operator fell asleep momentarily at wheel during ascent from pit. Truck drifted toward windrow. Operator woke and corrected. End of 12-hour night shift. Fatigue monitoring system was installed but not calibrated for this operator.

Near MissHighUnder Investigation
009622 DecProcessing Plant — Level 1

Isolation lock found to have incorrect tag — lock belonged to different work crew than those currently working on the equipment. Cross-referencing with permit showed mismatch.

Hazard ReportMediumClosed
009520 DecLaydown Area

Forklift operator misjudged clearance and struck storage rack while placing pallet. Rack sustained minor structural damage. No falling objects. Load was secured.

Property DamageLowClosed
009418 DecCrusher Area

Rock fragment (~5kg) ejected from primary crusher during processing of oversized material. Fragment struck safety screen but screen had visible corrosion damage. Fragment would have entered walkway if screen had failed.

Near MissHighClosed
009316 DecMain Gate / Weighbridge

Pedestrian crossed vehicle access road without using designated crossing. Light vehicle braked to avoid. Pedestrian was a visitor who had completed induction but was unfamiliar with traffic management layout.

Near MissLowClosed
009214 DecProcessing Plant — Level 3

EWP (elevated work platform) operator raised basket beyond maximum rated height. Stability alarm sounded. Operator lowered immediately. Operator stated the height limiter appeared to be malfunctioning.

Near MissMediumClosed
009111 DecFuel Farm

Lightning strike recorded within 5km of fuel farm during overnight storm. Automated shutdown protocol activated correctly. Manual verification found one earthing strap on storage tank not connected.

Hazard ReportMediumClosed
009010 DecPit 4 Haul Road

Grader blade left extended across haul road during operator break. Haul truck operator noticed at last moment and stopped. Grader was parked in active traffic area without cones or signage.

Near MissMediumClosed
008908 DecWater Treatment Plant

pH sensor on discharge line giving erratic readings. Manual testing confirmed normal pH levels. Sensor malfunction could have masked an actual exceedance if not caught.

Hazard ReportLowClosed
008806 DecProcessing Plant — Level 2

Scaffold plank fell from Level 2 to ground level during scaffold disassembly. Area below was barricaded but barricade had been moved by unknown person. No one in impact zone.

Near MissMediumClosed
008703 DecPower Station

Backup generator auto-started during planned maintenance on main power distribution board. Isolation procedure did not include backup generator interlock. Maintenance crew narrowly avoided energised bus bar.

Hazard ReportCriticalUnder Investigation
008602 DecStockpile Area

Subsidence noticed on stockpile pad surface. Dozer operator felt ground shift. Area evacuated and assessed. Underground drainage pipe had partially collapsed creating void beneath surface.